Code: E020-01A0
Description: Toner density sensor (Y) output lower limit error. The toner density sensor output (Vsig_ind) is less than 43.
Remedy: 1. Check the connection between the toner density sensor and the DC controller PCB. (Connector, Breaking (shorting)) <Y> sensor side: J7133, J8028, J8087 PCB side: J1244, J8085 <M> sensor side: J7134, J8029, J8088 PCB side: J1244, J8085 <C> sensor side: J7135, J8030, J8089 PCB side: J1244, J8086 <Bk> sensor side: J7146, J8015, J8117 PCB side: J1244, J8080 2. Check whether disconnection or shorting of the toner density sensor occurs or not. 3. Replace the developing assembly