Code: 025-0210-05
Description: Toner Container reciprocation HP timeout error (M)
Causes: The Toner Container Reciprocation HP Sensor (M) did not detect home position within the specified period of time.
Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN2/J1247) and the Toner Container Drive Motor (M) (M13/J7101) - Harness between the DC Controller PCB (UN2/J1249) and the Toner Container Reciprocation HP Sensor (M) (PS14/J1980) - Toner Container Drive Motor (M) (M13) - Toner Container Reciprocation HP Sensor (M) (PS14) - Hopper Unit (M) - DC Controller PCB (UN2) [Remedy] Perform the following in the order while checking whether the error is cleared. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. 1. If the Toner Container Reciprocation HP Sensor (M) is soiled, clean it with a blower. 2. Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES