Code: 025-04A0-05
Description: Toner Container phase detection error (Bk)
Causes: The Toner Container Phase Sensor (Bk) did not detect the open state when opening the Toner Container Cap.
Remedy: [Related parts] R1.00 - Harness connecting from the DC Controller PCB (UN2/J1248) to the Toner Container Reciprocation HP Sensor (Bk) and Toner Container Phase Sensor (Bk) (PS8/J1750 and PS84/ J7129) - Toner Container Reciprocation HP Sensor (Bk) (PS8) - Toner Container Phase Sensor (Bk) (PS84) - DC Controller PCB (UN2) - Developing Drive Unit (Bk) [Remedy] Perform the following in the order while checking whether the error is cleared. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. 1. Check the installation of the sensor and whether it is soiled. 2. Move the Hopper Unit (Bk) little by little with the Toner Container Removing Tool, and check if the output value of "COPIER> I/O> DC-CON> P035 bit13" is changed. a. If the output value of the sensor is changed, check the gears of the Hopper Unit. If they are damaged, replace the Developing Drive Unit (Bk). b. If the output value of the sensor is not changed, check/replace the related harness/cable, connector and parts. After a recovery from the error, go through the following to check that toner can be replaced properly (the removed toner container can be installed again): "Adjustment/Maintenance> Maintenance> Replace Specified Toner". [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES