Mã lỗi 074-0002-05 — Canon iR Advance C7565i

Code: 074-0002-05

Description: ITB Unit pressure error
Causes: When applying pressure on the ITB Unit (at power-on/recovery from sleep/opening and closing of the door), pressure failure was detected.
Remedy: [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Check that the ITB Pressure Release Lever is in the engaged state. 2. When pulling out the ITB Unit, check that the unit is on the rails and the edges of the 2 ITB Pressure Arms at the front side of the unit are fitted in the grooves of the ITB Frame. [CAUTION] If the ITB Pressure Arm is soiled with toner, clean it with a cloth tightly wrung out of water. 3. Check that the shafts of the Primary Transfer Roller are fitted in the Shaft Support.