Code: 260-0541-05
Description: Power supply error
Causes: The 24 V/12 V supply to the Developing Cooling Suction Fans (Y, M and C) were not detected. (Blowout of FU3 and 4 on the Developing Assembly Control PCB)
Remedy: [Related parts] R1.00 - Harnesses connecting from the Developing Assembly Control PCB (UN96/J1304) to the Drawer Unit (J8031) to the Developing Cooling Suction Fan (Y, M and C) (FM36/J8920, FM37/J8918 and FM38/J8919) - Developing Cooling Suction Fan (Y, M and C) (FM36, FM37 and FM38) - Developing Assembly Control PCB (UN96) [Remedy] Check/replace the related harness/cable, connector and parts.