Code: 551-0001-02
Description: a. Error in the Power Supply Fan of the Finisher (Finisher-X1) b. Error in the Power Supply Fan (Document Insertion Unit-N1; Location Inf. 71)
Causes: a. The loch signal is detected 1.2 sec. or more while the fan operates. b. Fan lock detection signal is detected ON while the Power Supply Fan is driven or Fan lock detection signal is detected OFF while thePower Supply Fan is stopped.
Remedy: a. STAPLE FIN-X1/BOOKLET FIN-X1 [Related parts] - Harnesses from the Power Supply Fan (FAN101) to the Finisher Controller PCB - Power Supply Fan (FAN101) - Finisher Controller PCB (PBA101) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] When replacing the Finisher Controller PCB, refer to "Adjustments> Adjustment when Replacing the Parts" in the Service Manual. b. INSERTION UNIT-N1 [Related parts] - Harnesses from the Insertion Unit Controller PCB (PCB3) to the Power Supply Fan (F1) - Insertion Unit Controller PCB (PCB3) - Power Supply Fan (F1) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] - When replacing the Insertion Unit Controller PCB, refer to "Adjustments> Adjustment when Replacing the Parts" in the Service Manual.