Mã lỗi 001-0011-05 — Canon iR Advance C7570i

Code: 001-0011-05

Description: Fixing Thermistor high temperature detection error
Causes: The Fixing Film Unit Main Thermistor detected an abnormally high temperature.
Remedy: [Related parts] R1.00 - Harnesses connecting the Pickup Driver PCB (UN4/J1491), the Drawer Unit (J8001) and the Fixing Thermistor Unit 1 (THM11/J7404) - Fixing Film Unit - Pickup Driver PCB (UN4) [Remedy] Perform the following in the order while checking whether the error is cleared. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. 1. Check the harness between the Pickup Driver PCB and the Fixing Film Unit Main Thermistor. 2. Pull out the Fixing Feed Unit and check "FIX-UC". a. In the case of below 240 deg C, replace the Fixing Film Unit. b. In the case of 240 deg C or higher, disconnect the connector of the Pickup Driver PCB and then check "FIX-UC" again. b-a. In the case of below 240 deg C, replace the harness between the Pickup Driver PCB and the Drawer Unit. b-b. In the case of 240 deg C or higher, replace the Pickup Driver PCB.