Code: 029-6000-05
Description: Patch Sensor error
Causes: An upper limit error in the light intensity of the Patch Sensor was detected when executing the initial installation mode of the Developing Assembly.
Remedy: [Related parts] R1.00 - Harness between the Multi Driver PCB (UN97/J1353) and the Patch Sensor (PS21/J7412) - Patch Sensor (PS21) - Intermediate Transfer Belt - Multi Driver PCB (UN97) [Remedy] Perform the following in the order while checking whether the error is cleared. - Check the value in COPIER> ADJUST>DENS >BASE-T. a. If the value of BASE-T is "1023", a-1. Execute COPIER> FUNCTION> SENS-ADJ> PCHINITC. a-2. Enter the value of "BASE-T" written on the service label in COPIER> ADJUST> DENS> BASET. a-3. Enter the value of "BASE-T" in COPIER> ADJUST> DENS> ALF-ATR. a-4. Initialize the Developing Assembly. b. If the value of BASE-T is not "1023", b-1. If the sensor surface of the Patch Sensor is soiled, clean it with a cloth tightly wrung out of water. b-2. Check/replace the related harness/cable, connector and parts.