Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 061-0002-05 — Canon iR Advance C7570i

Code: 061-0002-05

Description: Potential Sensor offset error
Causes: It was detected that the result of offset adjustment of the Potential Sensor was +/- 30 V or more.
Remedy: [Related parts] R1.00 - Harness between the Multi-purpose Tray Pickup Driver PCB (UN97/J1355) and the Potential Control PCB (UN29/J3530) - Harness between the Potential Control PCB (UN29/J3531) and the Potential Sensor (UN160/ J8073) - Potential Sensor (UN160) - Potential Control PCB (UN29) - Multi-purpose Tray Pickup Driver PCB (UN97) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Check the installation of the electrode for checking the Potential Sensor. 2. Check/replace the related harness/cable, connector and parts. [Reference] After replacement of the Potential Control PCB Unit, execute offset adjustment of the Potential Sensor by referring to "Parts Replacement and Cleaning Procedure> Image Formation System> Potential Sensor> When Replacing the Potential Control PCB" in the Service Manual.

← Xem tất cả mã lỗi Canon iR Advance C7570i