Code: 074-0001-05
Description: Primary Transfer Roller disengagement HP timeout error
Causes: The Primary Transfer Roller Detachment HP Sensor did not detect home position within the specified period of time.
Remedy: [Related parts] R1.00 - Harness between the ITB Relay PCB (UN28/J2701) and the Primary Transfer Roller Detachment HP Sensor (PS4/J7113) - Harnesses connecting the DC Controller PCB (UN2/J1240), the Drawer Unit (J8050) and the ITB Relay PCB (UN28/J2700) - Primary Transfer Roller Detachment HP Sensor (PS4) - ITB Relay PCB (UN28) - DC Controller PCB (UN2) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Check that the Primary Transfer Roller (Pressure Release Lever, Link and Cam) is free of foreign matter or soiling. 2. Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES