Code: 260-0152-05
Description: Power supply error
Causes: The 5 V supply to the Sheet Width Sensor was not detected. (Blowout of FU13, 14, 15 and 16 on the Fixing Feed Driver PCB)
Remedy: [Related parts] R1.00 - Harness connecting from the Fixing Feed Driver PCB (UN5/J1512) to the Sheet Width Sensor 1, 2, 3 and 4 (PS94/J8618, PS95/J8519, PS96/J8520 and PS97/J8621) - Sheet Width Sensor 1, 2, 3 and 4 (PS94, 95, 96 and 97) - Fixing Feed Driver PCB (UN5) [Remedy] Check/replace the related harness/cable, connector and parts.