Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi E002-0102 — Canon iR Advance C9060 Pro

Code: E002-0102

Description: Insufficient pressure belt temperature rise 1. In a warm-up, the temperature of pressure main thermistor (THM2) does not reach to 80 degrees Celsius within 250 seconds after reaching to 50 degrees Celsius.
Remedy: 1. Check if the detection temperature of the thermistor is risen in service mode. A. In case that either one of the thermistor detection temperature is risen A-1. Check the pressure belt main thermistor (to see if the thermistor is disconnected, the harness of the thermistor is disconnected, foreign substance is in the thermistor, failure of the thermistor) -> replace the pressure main thermistor or the pressure stay A-2. Faulty drawer connector -> clean the drawer connector or replace the fixing assembly B. In case that neither of them are not risen B-1. Check the connection of the AC driver connector (to see if the connector is physically removed or disconnected, or the cable is caught) B-2. Replace the AC driver unit B-3. Replace the DC controller PCB B-4. Replace the fixing assembly

← Xem tất cả mã lỗi Canon iR Advance C9060 Pro