Mã lỗi E009-0502 — Canon iR Advance C9060 Pro
Code:
E009-0502
Description: Pressure unit pressure application timeout error. Pressure application operation could not be completed within a specified period.
Remedy: 1. Check the fixing pressure release drive gear -> replace the gear 2. Replace the fixing pressure release sensor (PS73) 3. Replace the fixing pressure release motor (M47) 4. Replace the fixing feed driver PCB 5. Replace the DC controller PCB