Code: E020-0082
Description: Patch sensor light intensity correction error. When executing correction of patch sensor light intensity, the P wave output is not more than 500 and less than 900.
Remedy: When the value of DISPLAY > DENS >P-LED-DA is large (153(D) or more) and the value of DISPLAY > DENS >P-SENS-P is small, there is a high possibility that dirt is applied to the patch sensor. This occurs only at a regular timing. When the value of DISPLAY>DENS>DENS-S-x is small (2 digits), there is a high possibility that breaking occurred. 1. Clean the patch sensor. 2. Check the connection between the patch sensor and the DC controller interface PCB. (Connector, Shorting) Sensor side: J7412, J8035 PCB side: J1242 3. Check open/close operation of the patch shutter. 4. Check whether scratches/dirt are applied to the ITB. If many scratches are found, replace the ITB. If dirt is applied, clean the ITB. In this case, check the ITB cleaning blade at the same time. 5. Replace the patch sensor unit.