Code: E061-0001
Description: Primary charging bias (Bk) lower limit error. At initial rotation, the drum surface potential Vd at potential control is less than 30V. Primary charging bias (Bk) is not properly applied. The drum does not rotate correctly.
Remedy: 1. Check whether the primary charging assembly is properly installed or connected. (Connection of the connector, Shorting, Wire caught by parts) 2. Check whether the primary charging high-voltage PCB (Bk) is properly installed or connected. (Connection of the connector, Shorting, Wire caught by parts) 3. Check whether the drum motor (Bk) is properly installed or connected. (Connection of the connector, Shorting, Wire caught by parts) 4. Replace the parts. Primary charging assembly Primary charging high-voltage PCB (Bk) Drum/ITB drive motor DC controller interface PCB DC controller PCB