Mã lỗi E003-0003 — Canon iR Advance C9070 Pro

Code: E003-0003

Description: Perssure belt abnormally low temperature. After went in standby, Pressure sub thermistor 1(THM3) detected less or equal to 50 degrees Celsius for specified time (250sec)
Remedy: 1. Check if the detection temperature of the thermistor is risen in service mode. A. In case that either one of the thermistor detection temperature is risen A-1. Check the pressure sub thermistor 2 (to see if the location of the thermistor is inappropriate, the harness of the thermistor is disconnected, failure of the thermistor) -> replace the pressure sub thermistor or the pressure stay A-2. Faulty drawer connector -> clean the drawer connector or replace the fixing assembly B. In case that neither of them are not risen B-1. Check the connection of the AC driver connector (to see if the connector is physically removed or disconnected, or the cable is caught) B-2. Replace the AC driver unit B-3. Replace the DC controller PCB B-4. Replace the fixing assembly