Mã lỗi E002-0002 — Canon iR Advance C9075 Pro

Code: E002-0002

Description: Insufficient fixing belt temperature rise 1. In a warm-up, the temperature of fixing main thermistor (THM1-1) does not reach to 80 degrees Celsius within 120 seconds after reaching to 50 degrees Celsius
Remedy: 1. Check if the detection temperature of the thermistor is risen in service mode. A. In case that either one of the thermistor detection temperature is risen A-1. Replace the fixing belt unit A-2. Faulty drawer connector -> clean the drawer connector or replace the fixing assembly B. In case that neither of them are not risen B-1. Check the connection of the fixing thermistor (to see if the connection of the drawer connector is faulty, the connector is physically removed or disconnected) -> replace the fixing belt unit B-2. Check the connection of the IH power connector (to see if the connector is physically removed or disconnected, or the cable is caught) B-3. Replace the IH power unit B-4. Replace the DC controller PCB