Code: E012-0401
Description: A.Drum Speed Detection PCB (Bk) 1/2 signal error (Controller Version 2x.xx or later) B.Drum motor (Bk) error (Prior to Controller Version 1x.xx). A.This error occurs when the Drum Speed Detection PCB (Bk) 1/2 signal error is detected. B.The lock signal for the drum motor (Bk) (M19) cannot be detected within a specified period.Connector disconnected, Breaking (Breaking (shorting)) - Connector disconnected, Breaking (Breaking (shorting)) - Drum (unit) not inserted - Drum unit failure - Encoder failure (This occurs in very rare cases.)
Remedy: A: 1. Check the connection of the Drum Speed Detection PCB (Bk) 1/2 (UN18/19). (Sensor side) Sensor side: J7310, J7311 2. Check that the Encoder Wheel of the Drum Speed Detection PCB (Bk) 1/2 is properly installed. 3. Check the connection of the Drum ITB Driver PCB (UN6). PCB side: J1911 4. Take out the Drum Speed Detection PCB (Bk) 1/2 to clean the Drum Speed Detection PCB (Bk) 1/2 (UN18/19) and Encoder Wheel. 5. Replace the Drum Speed Detection PCB (Bk) 1/2 (UN18/19). 6. Replace the Drum ITB Driver PCB (UN6). B: 1. Check the connection between the drum motor (Bk) (M19) and the drum ITB driver PCB (UN6). (Connection of the connector, Breaking (Breaking (shorting))) Motor side: J7306, PCB side: J1921 2. Check the connection between the drum speed detection PCB (Bk) (UN24/23) and the drum ITB driver PCB (UN6). (Connection of the connector, Breaking (Breaking (shorting))) Motor side: J7310/J7311, PCB side: J1911 3. Reinstall the drum unit (Bk). 4. Replace the drum cleaning unit and the drum unit. (Drum drive may be overloaded due to peeling of the blade, etc.) 5. Replace the drum ITB driver PCB (UN6). MEMO: In some rare cases, this error occurs when the encoder is not installed with the drum speed detection PCB or when dirt is applied to the sensor surface of the drum speed detection PCB.