Code: E074-0001
Description: Primary transfer roller detachment/attachment error. The primary transfer roller attachment/detachment HP sensor (PS4) cannot detect the home position within a specified period
Remedy: 1. Check the connection between the primary transfer roller detachment HP sensor (PS4) and the ITB relay PCB (UN28). (Connector, Breaking (shorting)) Sensor side: J7113 PCB side: J2701 2. Check the connection between the ITB relay PCB and the DC controller PCB. (Connector, Breaking (shorting)) ITB relay PCB: J2700, J8050 DC controller PCB: J1241, J8010 3. Replace the primary transfer roller detachment HP sensor. 4. Check the link parts of the primary transfer roller (pressure release lever, link, cam). If foreign matters are found, remove them. If they are soiled with toner, etc., perform cleaning (when the parts do not move smoothly due to dirt). 5. Check whether the gear is not damaged. If it is damaged, replace the attachment/detachment drive unit (FM3-4905).