Description: Exposure Lamp Error
At trigger on, the lamp was not detected on.
Causes: • Exposure lamp defective
• Lamp regulator defective
• Lamp regulator harness damaged, disconnected
• Dirty standard white plate
• Scanner mirror dirty or out of position
• Lens dirty, out of position