Code: E719-0001
Description: Erroneous communication with coin vendor (serial communication)
- Disconnection from the coin vendor has been detected since communication started after confirmation of normal connection to the coin vendor (after power-on).
- A serial communication error has occurred. (The serial communication error cannot be recovered.)
- Disconnection from the coin vendor has been detected since communication started after confirmation of normal connection to the coin vendor (after power-on).
- A serial communication error has occurred. (The serial communication error cannot be recovered.)
Remedy: - Check the connection between the image processor PCB and serial PCB. - Check the connectors of the serial PCB and coin vendor for normal connection. - Replace the serial PCB. - Check the coin vendor. - Replace the image processor PCB