Description: The BD PCB is faulty.
The BD signal does not arrive within 1 sec after the laser drive signal has been generated. Or, the BD signal does not arrive for 1 sec or more while the laser remains ON.
Remedy: - Check if the BD PCB, laser driver PCB and DC controller are connected properly. - Replace the BD PCB. - Replace the laser scanner unit. - Replace the DC controller PCB.