Description: Error in fixing power supply drive circuit
Causes: Failed to detect the zero cross signal for the specified period of time or more.
Remedy: 1. Check the connection of connector between the Fixing Assembly and the Engine Controller PCB. 2. Replace the Fixing Assembly. 3. Replace the Engine Controller PCB.