Code: E500
Description: An error has occurred in the communication between the machine and the finisher twice continuously.
Causes: The harness to the finisher is faulty (disconnected connector, open circuit). The finisher controller PCB or the DC controller PCB is faulty.
Remedy: 1) Power switch Try turning off and then on the power switch. Is the fault corrected? YES : End. 2) Wiring Is the wiring from the finisher controller PCB to the DC controller PCB normal? NO : Corrected the wiring. 3) Finisher controller PCB, DC controller PCB Try replacing the finisher controller PCB. Is the fault corrected? YES : End. NO : Replace the DC controller PCB.