Code: E580
Description: The stack tray upper limit sensor (S1) goes ON while the stack tray up/down motor (M5) is in operation.
The clock signal of the stack tray up/down clock sensor (S9) is not detected 15 times or more within 0.8 sec while the stack tray up/down motor (M5) is in operation.
It does not reach the stack tray paper height sensor (S10) 2 sec after the stack tray up/down motor (M5) rotates for ascent.
It does not leave the stack tray power height sensor (S10) 2 sec after the stack tray up/down motor (M5) starts to rotate for descent.
The clock signal of the stack tray up/down clock sensor (S9) is not detected 15 times or more within 0.8 sec while the stack tray up/down motor (M5) is in operation.
It does not reach the stack tray paper height sensor (S10) 2 sec after the stack tray up/down motor (M5) rotates for ascent.
It does not leave the stack tray power height sensor (S10) 2 sec after the stack tray up/down motor (M5) starts to rotate for descent.
Causes: The stack tray up/down motor (M5) is faulty. The stack tray paper height sensor (S10) is faulty. The sensor connector is disconnected or has an open circuit. The stack tray up/down clock sensor (SW9) is faulty. The sensor connector is disconnected or has an open circuit. The stack tray up/down motor is subjected to an abnormal load. The finisher controller PCB is faulty.
Remedy: 1) Stack tray up/down motor (encoder) Try turning the encoder of the stack tray up/down motor by hand. Does it rotate smoothly? NO : Correct the mechanical mechanism. 2) Wiring Is the wiring between the finisher controller PCB and the stack tray up/down motor (M5) normal? NO : Correct the wiring. 3) Tray phase Is the left/right phase of the stack tray normal? NO : Correct the phase. 4) Stack tray up/down lock sensor (S9) Check the stack tray up/down clock sensor (S9). Is the sensor normal? NO : Replace the sensor. 5) Stack tray paper height sensor (S10) Check the stack tray paper height sensor (S10). Is the sensor normal? NO : Replace the sensor. 6) Stack tray paper limited sensor (S1), Stack tray lower limit sensor (S12) Check the stack tray upper limit sensor (S1) and the stack tray lower limit sensor (S12). Are the sensors normal? NO : Replace the sensors. 7) Stack tray up/down motor (M5), Finisher controller PCB Try replacing the stack tray up/down motor (M5). Is the fault corrected? YES : End. NO : Replace the finisher controller PCB.