Code: E585
Description: The stack retaining lever does not reach home position when the stack handling motor (M2) has been driven for a specific time (at the start of motor CCW rotation). (If the same condition is detected during stack delivery, a jam will be identified)
Causes: The stack handling motor (M2) is faulty. The stack delivery lever home position sensor (S8) is faulty. The sensor connector is disconnected or has an open circuit. The stack handling motor relay harness is faulty. The stack retaining lever is faulty. The finisher controller PCB is faulty.
Remedy: 1) Stack holding motor drive belt. Is the tension of the drive belt appropriate? NO : Loosen the screw, and correct the tension. 2) Stack handling motor (drive mechanism) Is the return roller rotating while the motor is rotating CCW? NO : Correct that drive mechanism. 3) Wiring Is the wiring between the finisher controller PCB and the stack handling motor (M2) normal? NO : Correct the wiring. 4) Stack retaining lever home position sensor (S4) Check the stack retaining lever home position sensor (S4). Is the sensor normal? NO : Replace the sensor. 5) Stack handling motor (M2), Finisher controller PCB Try replacing the stack handling motor (M2). Is the fault corrected? YES : End. NO : Replace the finisher controller PCB.