Code: E805
Description: After the heat discharge fan drive signal is generated, the fan lock detection signal does not arrive for a specific period of time.
Causes: The fan wiring is faulty (short circuit, open circuit). The heat discharge fan (FM101) is fautly. The DC controller PCB is faulty.
Remedy: 1) Foreign matter Is there foreign matter that prevents the rotation of the fan? YES : Remove the foreign matter. 2) Wiring, Connector Is the connection and wiring of the connector (J951) of the heat discharge fan (FM101) and the connector (J106) on the DC controller PCB normal? NO : Correct the wiring. 3) Heat discharge fan (FM101), DC controller PCB Try replacing the heat discharge fan (FM101). Is the fault corrected? YES : End. NO : Replace the DC controller PCB.