Code: E530-8001
Description: Front Alignment Motor (M4) error
At initialization of the Front Alignment Plate, the Front Alignment Plate failed to move from the Front Alignment Plate HP Sensor (S4) although the Front Alignment Motor (M4) was driven for 10 mm.
At initialization of the Front Alignment Plate, the Front Alignment Plate failed to move from the Front Alignment Plate HP Sensor (S4) although the Front Alignment Motor (M4) was driven for 10 mm.
Remedy: 1. Check the connector connection of the Front Alignment Plate HP Sensor (S4) or the Front Alignment Motor (M4). 2. Check for open circuit of the Harness of the Front Alignment Plate HP Sensor (S4) or the Front Alignment Motor (M4). 3. Replace the Front Alignment Plate HP Sensor (S4). 4. Replace the Front Alignment Motor (M4). 5. Replace the Finisher Controller PCB.