Description: Power Supply Cooling Fan (FM4) error
A lock signal was detected for 5 seconds while the Power Supply Cooling Fan (FM4) was being stopped. *The same status was detected again after executing an error retry.
Remedy: 1. Disconnect and then connect the connector (J209) on the DC Controller PCB (PCB1) to check the connection. 2. Replace the Power Supply Cooling Fan (FM4). 3. Replace the DC Controller PCB (PCB1).