Code: E002
Description: A start-up fault is detected under any of the following conditions of the main thermistor (start-up detection fault):
after exceeding 40°C, it fails to reach 60°C within 10 sec.
after exceeding 60°C, it fails to reach 80°C within 10 sec.
after exceeding 180°C, it fails to reach 195°C within 10 sec.
after exceeding 40°C, it fails to reach 60°C within 10 sec.
after exceeding 60°C, it fails to reach 80°C within 10 sec.
after exceeding 180°C, it fails to reach 195°C within 10 sec.
Causes:
Remedy: 1) Wiring Is the connection of the connector (CN8) on the power supply PCB and the connector (J103) on the DC controller PCB and the wiring to the fixing assembly normal? NO : Correct the connection and wiring. 2) Fixing assembly Try replacing the fixing assembly. Is the fault corrected? YES : End. 3) Power supply PCB, DC controller PCB Try repacking the power supply PCB. Is the fault corrected? YES : End. NO : Replace the DC controller PCB. 4) Error With the power switch ON, clear E000 through E004; then, turn off and then on the power switch.