Code: E010
Description: A specific revolution is not detected from the main motor rotation detection signal (MLOK*), causing the signal to go '1' (main motor fault)
Causes: The main motor (M101) is faulty. The controller PCB is faulty.
Remedy: 1) Connector Is the connection of the connector (J903) of the main motor and the connector (J06) on the DC controller PCB normal? NO : Correct the connection. 2) Main motor (M101), DC controller PCB Try replacing the main motor. Is the fault corrected? YES : Replace the main motor. NO : Check the wiring; if normal, replace the DC controller PCB.