Code: E577
Description: The return roller does not reach home position when the delivery motor (M1) is driven for a specific time. (If the same condition is detected while alignment takes place in the direction of feed, a jam will be identified)
Causes: The delivery motor (M1) on the finisher controller PCB is faulty. The return roller home position sensor (S3) is faulty. The connector is discontented or has an open circuit. The delivery motor relay harness is faulty. The return roller is faulty. The finisher controller PCB is faulty.
Remedy: 1) Delivery motor (drive mechanism) Is the return roller rotation when the motor is rotating CCW? NO : Correcting the drive mechanism. Is the return roller displaced? NO : Correct the return roller spring. Is the tension of the delivery motor drive belt appropriate? NO : Loosen the screw, and correct the tension. 2) Return roller home position sensor (S3) Check the return roller home position sensor (S3). Is the sensor normal? NO : Replace the sensor. 3) Delivery motor (M1), Finisher controller PCB Try replacing the delivery motor (M1). Is the fault corrected? YES : End. NO : Replace the finisher controller PCB.