Mã lỗi E002-001 — Canon iR2010

Code: E002-001

Description: After power-on/start of printing, the reading of the main thermistor does not reach the target value -15°C/11°F or higher within 75 sec. About 10 sec or later after the heater is supplied with power, the sub thermistor detects less than 75°C/167°F for 2 sec or more continuously.
Causes: - The fixing film unit is faulty (main thermistor fault, sub thermistor fault, thermal fuse blow, fixing heater fault). The power supply PCB is faulty. The DC controller PCB is faulty.
Remedy: 1. Malfunction Turn off the power; wait for 10 min, and turn on the power. Is the problem corrected? YES: End. 2. Wiring Is the wiring from the DC controller PCB to the fixing film unit normal? NO: Correct the wiring. 3. Fixing film unit Try replacing the fixing film unit. Is the problem corrected? YES: End. 4. Power supply PCB, DC controller PCB Try replacing the power supply PCB. Is the problem corrected? YES: End. NO: Replace the DC controller PCB.