Code: E540-0005
Description: - Standard tray shift motor or finisher controller PCB failure
- Standard tray HP sensor failure - Standard tray clock sensor failure
- Standard tray shift motor load failure The encoder clock signal was not detected two or more times when the standard tray was operated for 300 ms.
- Standard tray HP sensor failure - Standard tray clock sensor failure
- Standard tray shift motor load failure The encoder clock signal was not detected two or more times when the standard tray was operated for 300 ms.
Remedy: - Check the connector of the standard tray HP sensor. - Check the connector of the standard tray clock sensor. - Check the connector of the standard tray shift motor. - Replace the standard tray HP sensor. - Replace the standard tray clock sensor. - Replace the standard tray shift motor. - Replace the finisher controller PCB.