Description: The aligning plate home position sensor (S6) does not go ON when the front alignment motor (M3) is driven for a specific number of rotations. The aligning plate home position sensor (S6) does not go OFF when the front alignment motor (M3) is driven for a specific number of rotations
Causes: The front alignment motor (M3) is faulty. The front aligning plate home position sensor (S6) is faulty. The front alignment motor relay harness is faulty. The front aligning plate is subjected to an excess load.