Code: E710-0001
Description: When the main power is turned on, the communication IC (IPC) on the reader controller PCB cannot be initialized
Causes: The DC controller PCB is faulty. The reader controller PCB is faulty. The machine controller PCB is faulty.
Remedy: Turn off and then on the main power switch. Is the problem corrected? YES: End. NO: If E7100001, replace the reader controller PCB. If E710-002, replace the DC controller PCB. If E71-0003, replace the main controller PCB.