Mã lỗi E713-0000 — Canon iR2220

Code: E713-0000

Description: The communication with the finisher is not resumed 3 sec or more after it is disrupted
Causes: The connector has poor connection. The option power supply PCB is faulty. The finisher controller PCB is faulty. The DC controller PCB is faulty.
Remedy: 1. Connector Is the wiring between the finisher controller PCB and the options power supply PCB and between the options power supply PCB and the DC controller PCB normal? NO: Correct the wiring. 2. Options power supply PCB Is the voltage between HJ701-6 (+) and J701-7 (-) on the options power supply PCB about 24 V? NO: Replace the options power supply PCB. 3. Finisher controller PCB, DC controller PCB Try replacing the finisher controller PCB. Is the problem corrected? YES: End. NO: Replace the DC controller PCB.