Code: E717-0001
Description: The communication with the DA unit is not resumed 3 sec or more after it is disrupted.
Causes: The wiring is faulty (short circuit, open circuit). The DA unit PCB is faulty. The main controller PCB is faulty. Caution To clear the error, execute the following in service mode: COPIER>FUNCTION>CLEAR>ERR.
Remedy: 1. Connector Is the connection between the DA unit PCB and the main controller PCB secure? NO: Correct the connection. 2. DA unit PCB, main controller PCB Try replacing the DA unit PCB. Is the problem corrected? YES: End. NO: Replace the main controller PCB.