Description: The edge gain correction level is different from the correction level for the preceding sheet by a specific level or more
Causes: The scanning lamp is faulty. The CCD PCB is faulty. The rear controller PCB is faulty.
Remedy: 1. Scanning lamp (LAMP1) Is the lamp ON during the initial operation after the main power switch is turned on? NO: Replace the scanning lamp. 2. CCD unit, Reader controller PCB Try replacing the CCD unit. Is the problem corrected? YES: End. NO: Replace the reader controller PCB.