Code: E302-0002
Description: During stream reading, the edge white addition processing does not end on the rear controller PCB after 10 sec
Causes: The CCD PCB is faulty. The wiring is faulty (short circuit, open circuit). The reader controller PCB is faulty
Remedy: 1. Connector Are the connectors (J6001/J6002) on the CCD PCB and the connectors (J5002/J5003) on the reader controller PCB connected securely? NO: Connect the connectors securely. 2. CCD unit Try replacing the CCD unit. Is the problem corrected? YES: End. 3. Reader controller PCB, Main controller PCB Try replacing the reader controller PCB. Is the problem corrected? YES: End. NO: Check the wiring; if normal, replace the main controller PCB.