Description: Unstable rotation of the Power Supply Cooloing Fan (FAN6)
When lock signal failed to be detected for 5 sec while the Power Supply Cooloing Fan (FAN6) is driven.
* The same condition is detected after the error retry is performed.
Remedy: 1.Disconnect and then connect the connector (J205) on the DC Controller PCB (PCB4). 2.Replace the Power Supply Cooloing Fan (FAN6). 3.Replace the DC Controller PCB (PCB4).