Description: Release Motor (M2) error
The sensing level of the release motor HP sensor (SR11) does not change within a specified period when the release motor (M2) is driven.
Remedy: 1.Replace the Release Motor HP Sensor (SR11). 2.Replace the Release Motor (M2). 3.Replace the ADF Driver PCB.