Mã lỗi E001-0000 — Canon iR2800

Code: E001-0000

Description: The main thermistor detects 250C or higher
Causes: The fixing film unit is faulty (i.e., the thermistor has a short circuit). The main power supply PCB is faulty. The DC controller PCB is faulty. Caution To clear the error, execute the following in service move: COPIER>FUNCTION>CLEAR>ERR.
Remedy: Check the interval between pin 1 and pin 2 and between pin 3 and pin 4 of the connectors (4-pin) of the thermistor for electrical continuity. Is it 0 W (short circuit)? YES: The thermistor has a short circuit. Replace the fixing film unit. If the thermistor has a short circuit, the indication in service mode (COPIER>DISPLAY>ANALOG) will be as follows from the start: FIXC= 250°C for the main thermistor; FIX-E=310°C for the sub thermistor. 2. Main power supply PCB, DC controller PCB Try replacing the main power supply PCB. Is the problem corrected? YES: End. NO: Replace the DC controller PCB.