Description: After the main motor drive signal is generated, the clock signal does to arrive within 1.3 sec
Causes: The main motor (M2) is faulty. the DC controller PCB is faulty.
Remedy: 1. Connector Is the connector of the main motor connected? NO: Connect the connector. 2. Main power supply PCB Is the drive voltage (24 V) of the main motor supplied by the main power supply PCB? Main power supply PCB: between J202-1 (24VU1-SW) and J202-2 (OVU1) NO: Replace the main power supply PCB. 3. Main controller (M2), DC controller PCB Press the Start key. Is the lock signal of the main motor present at the connector J308 on the DC controller PCB? Lock signal: J318-A10 (MM_LOCK) YES: Replace the main motor. NO: Check the wiring; if normal, replace the DC controller PCB.