Code: E712-0001
Description: The communication is not resumed 3 sec or more after data has been written to the error register of the communication IC (IPC) on the ADF controller PCB
Causes: The connect has poor connection. The main power supply PCB is faulty. The ADF controller PCB is faulty. The reader controller PCB is faulty.
Remedy: 1. Connector Is the interface able between the ADF controller PCB and the reader controller PCB normal? NO: Correct the cable. 2. Main power supply PCB While the ADF is in operation, does the voltage between J203-2 (+) and J203-1 (-) on the main power supply PCB change from 0 to about 24 V? NO: Replace the main power supply PCB. 3. ADF controller PCB, Reader controller PCB Try replacing the ADF controller PCB. Is the problem corrected? YES: End. NO: Replace the rear controller PCB.