Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi E002-0000 — Canon iR2820

Code: E002-0000

Description: The temperature of the fixing film is as follows:
has exceeded 100C, but does not reach 115C within 1 sec thereafter. has exceeded 140C, but does not reach 150C within 1 sec thereafter. has exceeded 160C, but does not reach 165C within 1 sec thereafter
Causes: The fixing film unit is faulty (i.e., the main thermistor TH1 has poor contact, or the fixing heater is faulty). The main power supply PCB is faulty. The DC controller PCB is faulty. Caution To clear the error, execute the following in service mode: COPIER>FUNCTION>FCLEAR>ERR.
Remedy: 1. State Turn on the power switch, and clear E002/E003. Thereafter, turn off and then on the power switch. Does the fixing heater operate? NO: See “The fixing heater fails to operate.” 2. Wiring Is the wiring from the DC controller PCB to the fixing film unit normal? NO: Correct the wiring. 3. Fixing film unit, DC controller PCB Try replacing the fixing film unit. Is the problem corrected? YES: End. NO: Replace the DC controller PCB.