Mã lỗi E051-0000 — Canon iR2820

Code: E051-0000

Description: At start-up, home position is not detected when the horizontal registration assembly is moved 100 mm in the direction of home position
Causes: The horizontal home position sensor is faulty. The horizontal registration motor is faulty. The DC controller PCB is faulty.
Remedy: 1. Connector Are the connectors of the horizontal registration home position sensor and the horizontal registration motor connected? a. DC controller PCB (J304) <-> relay connector <-> horizontal registration home position sensor b. DC controller PCB (J304) <-> relay connector <-> horizontal registration motor NO: Connect the connectors. 2. Sensor lever (damage and interference), Sensor Is abnormal noise heard from the horizontal registration assembly in keeping with the motor rotation? YES: a. The horizontal registration assembly is out of place because of damage to the sensor lever. Replace the sensor lever. b. The horizontal registration assembly malfunctions because of the presence of foreign matter. Remove the foreign matter. c. The sensor is faulty and cannot detect home position. Replace the sensor. 3. Horizontal registration motor, DC controller PCB Is the horizontal registration motor control signal generated by the DC controller PCB? J304-1/2: 24 V, J304-3/4/5/6: motor excitation signal YES: The horizontal registration motor is faulty. Replace the motor. NO: Replace the DC controller PCB.

← Xem tất cả mã lỗi Canon iR2820

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie