Code: E719-0001
Description: The communication between the Card Reader-C1 or the coin vendor and the main controller PCB is disrupted
Causes: The wiring is faulty (short circuit, open circuit). The Card Reader-C1 is faulty. The coin vendor is faulty. The main controller PCB is faulty. Caution To clear the error, execute the following in service mode: COPIER>FUNCTION>CLEAR>ERR.
Remedy: 1. Connector Is the Cad Reader-C1 or the coin vendor connected securely? NO: Connect it securely. 2. Coin vendor, Main controller PCB Try replacing the Card Reader-C1 or the coin vendor. Is the problem corrected? YES: End. NO: Replace the main controller PCB.