Code: SC311
Description: Drum Potential Sensor Error 2
When calibrating the drum potential sensor during process control initialization, the rate of change of drum potential sensor output with voltage on the drum is out of specification. NOTE: After this SC is issued, the grid voltage changes to the value set with SP2001-001 (Charge Corona Bias Adjustment) and LD power changes to the value set with SP2103 (LD Power Adjustment).
When calibrating the drum potential sensor during process control initialization, the rate of change of drum potential sensor output with voltage on the drum is out of specification. NOTE: After this SC is issued, the grid voltage changes to the value set with SP2001-001 (Charge Corona Bias Adjustment) and LD power changes to the value set with SP2103 (LD Power Adjustment).
Causes: • Drum potential sensor defective • Poor connection between the drum potential sensor and the BCU • Drum potential sensor defective • IOB defective • Poor drum ground connection • CBG power pack defective