Code: SC312
Description: Drum Potential Sensor Error 3 (Vd Abnormal)
When Vd on the surface of the unexposed drum is adjusted during process control initialization, -900 V is applied to the charge grid but Vd is more than -900. NOTE: After this SC is issued, the grid voltage changes to the value set with SP2001-001 (Charge Corona Bias Adjustment) and LD power changes to the value set with SP2103 (LD Power Adjustment).
When Vd on the surface of the unexposed drum is adjusted during process control initialization, -900 V is applied to the charge grid but Vd is more than -900. NOTE: After this SC is issued, the grid voltage changes to the value set with SP2001-001 (Charge Corona Bias Adjustment) and LD power changes to the value set with SP2103 (LD Power Adjustment).
Causes: • Drum potential sensor defective • Poor drum potential sensor harness connection • Drum potential sensor connector defective • IOB defective • Poor drum ground connection • Drum disconnected • Quenching lamp defective • CBG power pack defective • Charge corona wire dirty or defective